Parameter |
Detail |
Compatibility |
SNK Brushless Multifunctional Drill Handpiece |
Torque Range |
Adjustable up to 1.5 N.m |
Speed Range |
0-300 RPM |
Material |
Medical-grade stainless steel |
Adjustable Torque (1.5 N.m): Delivers consistent, repeatable torque for screw fixation, minimizing bone stripping or implant loosening in procedures like spinal fusion or fracture repair.
Variable Speed (0-300 RPM): Enables surgeons to adjust drilling speed for optimal control in dense bone or delicate tissue.
Seamless Integration: Designed exclusively for SNK’s Brushless Multifunctional Drill Handpiece, ensuring flawless compatibility and performance.
Autoclavable (134°C): Fully sterilizable to meet OR infection control protocols.
Corrosion-Resistant Material: Made from surgical-grade stainless steel for longevity and biocompatibility.
Ergonomic Design: Lightweight and balanced to reduce hand fatigue during prolonged use.
Zero Maintenance: Leverages SNK’s brushless motor technology for 50,000+ hours of maintenance-free operation.
Low Noise & Heat: Inherits the parent handpiece’s ultra-quiet (≤75dB) and low-heat (≤25℃) performance.
Precision Machining: CNC-machined components ensure micron-level accuracy for torque consistency.
Modular Design: Quick-connect mechanism allows rapid attachment/detachment without tools.
Spinal Surgery: Pedicle screw fixation, interbody cage placements.
Trauma Orthopedics: Fracture plate screw tightening, intramedullary nailing.
Joint Replacements: Precise implant seating in hip/knee arthroplasty.
Cost Efficiency: Eliminates need for standalone torque devices, reducing equipment costs.
Workflow Optimization: Integrates with existing SNK systems for seamless intraoperative tool switching.
The adapter is specifically engineered for seamless integration with the SNK Brushless Multifunctional Drill Handpiece system.
It delivers an adjustable torque range up to 1.5 N.m and a controllable variable speed range from 0 to 300 RPM for high-precision operations.
Yes, the adapter is manufactured from medical-grade surgical stainless steel and is fully autoclavable at 134°C to meet hospital OR infection control protocols.
It is widely used in spinal surgery (pedicle screw fixation), trauma orthopedics (fracture plate screw tightening), and joint replacement procedures.
No, it features a modular quick-connect mechanism that allows rapid attachment and detachment without additional tools during surgery.
Leveraging SNK's brushless motor design, the unit provides 50,000+ hours of maintenance-free operation with low acoustic noise (≤75dB) and reduced thermal output (≤25℃).